Bug
Enhancement
Other
01844 -
OTESTV3 - work order open/lookup infinite loop
Symptoms:
When looking up work orders by equipment, entered a wildcard character and the equipment list appeared. A message box was then displayed with the error, "ORA-01790: expression must have same datatype as corresponding expression." Had to use task manager to shut down application.
Solution:
This problem would only occur when running against an Oracle database. The SQL statement for expanding the work orders for the selected equipment has been changed to fix this error.